Three Phases Solar Inverter 10KVA 15KVA 20KVA 25KVA
-Pure sine wave output;
-Low DC voltage, saving system cost;
-Built-in PWM or MPPT charge controller;
-AC charge current 0-45A adjustable;
-Wide LCD screen, clearly and precisely shows icon data;
-100% imbalance loading design, 3 times peak power;
-Setting different working modes based on variable usage requirements;
-Various communication ports and remote recontrols (RS232/RS485/APP/SNMP/GSM optional).
- Description
- Inquiry
Description
⌈ Application Area ⌋
Medium IDC data exchange center machine room, medium scale network management system, billing center, bank/securities settlement center, industrial process control applications, traffic control areas, etc.
Provide stable, reliable and safe solutions for families, islands, ships and other small photovoltaic power system.
⌈ Technical Parameters ⌋
Specification | |||||
Model HDSX-T | 10KVA | 15KVA | 20KVA | 25KVA | |
Rated Power | 8KW | 12KW | 16KW | 20KW | |
Peak Power(20ms) | 24KW | 36KW | 48KW | 60KW | |
Starter Motor | 5HP | 7HP | 10HP | 10HP | |
Battery Voltage | 48/96/192VDC | 96/192/384VDC | |||
Size(L*W*Hmm) | 565*300*775 | ||||
Packing Size(L*W*Hmm) | 625*360*895 | ||||
N.W.(kg) | 122 | 134 | 160 | 176 | |
G.W.(kg)(Carton Packing) | 146 | 158 | 184 | 200 | |
Input | DC Input Voltage Range | 10.5VDC-15VDC(Single battery voltage) | |||
AC Input Voltage Range | 380Vac/400Vac±10%(customized 190Vac/200Vac) | ||||
AC Input Frequency Range | 45Hz-65Hz | ||||
Max AC charging current | 25A/15A/10A | 30A/20A/10A | 30A/20A/10A | 45A/30A/15A | |
AC charging method | Three-stage (constant current, constant voltage, floating charge) | ||||
Phase | 3/N/PE | ||||
Output | Efficiency(Battery Mode) | ≥85% | |||
Output Voltage(Battery Mode) | 380Vac/400Vac±10%(customized 190Vac/200Vac) | ||||
Output Frequency(Battery Mode) | 50/60Hz ±1% | ||||
Output Wave(Battery Mode) | Pure Sine Wave | ||||
Output waveform distortion | Linear load≤3% | ||||
Efficiency(AC Mode) | >99% | ||||
Output Voltage(AC Mode) | Conforming to AC input | ||||
Output Frequency(AC Mode) | Conforming to AC input | ||||
No load loss(Battery Mode) | ≤1% rated power | ||||
No load loss(AC Mode) | ≤2% rated power( charger does not work in AC mode) | ||||
No load loss(Energy saving Mode) | ≤10W | ||||
Phase | 3/N/PE | ||||
Battery type (Optional) | U0: Gel U.S.A | Charge Voltage:14V;Float Voltage:13.7V(Single battery voltage) | |||
U1: A.G.M.1 | Charge Voltage:14.1V;Float Voltage:13.4V(Single battery voltage) | ||||
U2: A.G.M.2 | Charge Voltage:14.6V;Float Voltage:13.7V(Single battery voltage) | ||||
U3: Sealed lead Acid | Charge Voltage:14.4V;Float Voltage:13.6V(Single battery voltage) | ||||
U4: Gel European | Charge Voltage:14.4V;Float Voltage:13.8V(Single battery voltage) | ||||
U5: Open lead Acid | Charge Voltage:14.8V;Float Voltage:13.5V(Single battery voltage) | ||||
U6: Calcuim(open) | Charge Voltage:15.1V;Float Voltage:13.6V(Single battery voltage) | ||||
U7: Sulphation cycle | 15.5V for 4hrs | ||||
customize battery | Charge and discharge parameters of different types of batteries (such as lithium batteries, etc.) can be customized according to user requirements. | ||||
Alarm | A | Normal working condition, buzzer has no alarm sound | |||
B | Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection | ||||
C | When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal |
⌈ System Application Diagram ⌋