Factory Wholesale Inverter With Solar Charger 1000W-7200W
Model: HP PRO-T inverter with solar charger
Place of Origin: China Manufacturer
Brand Name: XINDUN
Certificate: ISO9001:2015, CE, TUV, TLC, IEC, etc.
Accept OEM&ODM, Free Configuration of Solar Solutions
- Description
- Inquiry
Description
⌈ HP PRO-T Inverter With Solar Charger 1000W-7200W ⌋
1) High frequency inverter – The high frequency inverter with solar charger is made of high-frequency magnetic core material with small size and light weight, which greatly improves the output power density of the circuit, reduces the no-load loss of the inverter with solar charger, and improves the efficiency. Generally, the peak conversion efficiency of high frequency inverter with solar charger can reach more than 90%;
2) Built-in MPPT solar charging controller optional – the charging operation mode is MPPT, and the conversion efficiency is up to 99%, which can save 30%~60% of the solar panel compared with the traditional controller;
3) Pure sine wave output – The waveform output by the pure sine wave inverter with solar charger is good, and the distortion is also relatively low. In addition, the output waveform is basically the same as the AC waveform generated by the power grid. Moreover, the AC power quality output by the pure sine wave inverter with solar charger will be much better than that provided by the power grid.
4) The battery charging and discharging voltage parameters are adjustable – applicable to different types of batteries. The voltage is determined according to your battery. How much voltage is your battery? Then choose the charging voltage that matches the battery voltage. Generally, 1.5 times of battery voltage is selected for charging. This basically ensures that the battery can be fully charged to 97%.
5) Three working modes of inverter with solar charger- AC priority, battery priority and PV priority
5.1 PV priority mode – PV priority is used to supply power to the load. When the pv power is less than the load power, the energy storage battery and the pv power supply the load together. When there is no pv or the battery power is insufficient, if the mains power is detected, the inverter with solar charger will automatically switch to the mains power supply.
5.2 AC priority mode – no matter whether there is pv power or battery power, as long as the mains power is detected, the load is powered by the mains power. Only after the mains power failure is detected, the load is switched to pv power and battery power.
5.3 Battery priority mode – PV gives priority to power supply to the load. When the PV power is less than the load power, the energy storage battery and PV supply power to the load together. When there is no PV, the battery supplies power to the load separately. When the battery power is insufficient, if there is mains power detected, the inverter with solar charger will automatically switch to mains power.
⌈ HP PRO-T Inverter With Solar Charger 1000W-7200W Details⌋
⌈ HP PRO-T Inverter With Solar Charger 1000W-7200W Wiring diagram⌋
⌈ HP PRO-T Inverter With Solar Charger 1000W-7200W case⌋
⌈ HP PRO-T Inverter With Solar Charger 1000W-7200W Specification⌋
Specification | ||||||||||
Model: HP pro-T | 10212 | 15224 | 20224 | 32224L | 32224 | 50248L | 50248 | 72248 | ||
Rated Power | 1000W | 1500W | 2000W | 3200W | 3200W | 5000W | 5000W | 7200W | ||
Peak Power(20ms) | 3000VA | 4.5KVA | 6KVA | 9.6KVA | 9.6KVA | 15KVA | 15KVA | 21.6KVA | ||
Battery Voltage | 12VDC | 24VDC | 48VDC | |||||||
Product Size(L*W*Hmm) | 355x272x91.5 | 400x315x101.5 | 440x342x101.5 | 525x355x115 | ||||||
Package Size(L*W*Hmm) | 443x350x187 | 488x393x198 | 528x420x198 | 615x435x210 | ||||||
N.W(Kg) | 6.5 | 8.5 | 10 | 14 | ||||||
G.W(Kg) | 7.5 | 9.5 | 11 | 15.5 | ||||||
Installation Method | Wall-Mounted | |||||||||
PV | Charging Mode | MPPT | ||||||||
MPPT tracking voltage range | 15V-80VDC | 30V-100VDC | 120V-450VDC | 60V-140VDC | 120V-450VDC | |||||
Rated (recommended) operating voltage of PV array | 15V-30VDC | 30V-60VDC | 360VDC | 60V-90VDC | 360VDC | |||||
Max PV Input Voltage Voc (At the lowest temperature) | 120VDC | 500VDC | 180VDC | 500VDC | ||||||
PV Array Maximum Power | 840W | 1680W | 4000W | 3360W | 6000W | 4000Wx2 | ||||
MPPT tracking channels (input channels) | 1 | 2 | ||||||||
Input | DC Input Voltage Range | 10.5-15VDC | 21VDC-30VDC | 42VDC-60VDC | ||||||
Rated AC input voltage | 220VAC / 230VAC / 240VAC | |||||||||
AC Input Voltage Range | 170VAC~280VAC (UPS mode)/ 120VAC~280VAC(INV mode) | |||||||||
AC Input Frequency Range | 45Hz~55Hz(50Hz),55Hz~65Hz(60Hz) | |||||||||
Output | Output efficiency(Battery/PV Mode) | 94%(Peak value) | ||||||||
Output Voltage(Battery/PV Mode) | 220VAC±2% / 230VAC±2% / 240VAC±2% | |||||||||
Output Frequency(Battery/PV Mode) | 50Hz±0.5 or 60Hz±0.5 | |||||||||
Output Wave(Battery/PV Mode) | Pure Sine Wave | |||||||||
Efficiency(AC Mode) | >99% | |||||||||
Output Voltage(AC Mode) | Follow input | |||||||||
Output Frequency(AC Mode) | Follow input | |||||||||
Output waveform distortion Battery/PV Mode) | ≤3%(Linear load) | |||||||||
No load loss(Battery Mode) | ≤1% rated power | |||||||||
No load loss(AC Mode) | ≤0.5% rated power(charger does not work in AC mode) | |||||||||
Battery | Battery Type | VRLA Battery | Charge Voltage :13.8V; Float Voltage:13.7V(Single battery voltage) | |||||||
Customize battery | Charging and discharging parameters of different types of batteries can be customized according to user requirements (charging and discharging parameters of different types of batteries can be set through the operation panel) | |||||||||
Maximum charging current (mains + PV) | 120A | 100A | 110A | 120A | 100A | 120A | 100A | 150A | ||
Max PV Charging Current | 60A | 60A | 60A | 60A | 100A | 60A | 100A | 150A | ||
Max AC Charging Current | 60A | 40A | 50A | 60A | 60A | 60A | 60A | 80A | ||
Charging method | Three-stage (constant current, constant voltage, floating charge) | |||||||||
Protection | Battery low voltage alarm | Battery undervoltage protection value+0.5V(Single battery voltage) | ||||||||
Battery low voltage protection | Factory default: 10.5V(Single battery voltage) | |||||||||
Battery over voltage alarm | Constant charge voltage+0.8V(Single battery voltage) | |||||||||
Battery over voltage protection | Factory default: 17V(Single battery voltage) | |||||||||
Battery over voltage recovery voltage | Battery overvoltage protection value-1V(Single battery voltage) | |||||||||
Overload power protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | |||||||||
Inverter output short circuit protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | |||||||||
Temperature protection | >90°C(Shut down output) | |||||||||
Working Mode | Mains priority/PV priority/Battery priority(Can be set) | |||||||||
Transfer Time | ≤10ms | |||||||||
Display | LCD+LED | |||||||||
Thermal method | Cooling fan in intelligent control | |||||||||
Communication(Optional) | RS485/APP(WIFI monitoring or GPRS monitoring) | |||||||||
Environment | Operating temperature | -10℃~40℃ | ||||||||
Storage temperature | -15℃~60℃ | |||||||||
Noise | ≤55dB | |||||||||
Elevation | 2000m(More than derating) | |||||||||
Humidity | 0%~95% (No condensation) | |||||||||
Note: 1. Model of 10212/15224/20224/32224L/50248L only support mains priority mode and battery priority mode, PV priority work mode is not supported. 2. All specifications are subject to charge without prior notice. |
⌈ HP PRO-T Inverter With Solar Charger 1000W-7200W Factory⌋
⌈ XINDUN Power China Manufacturer & Supplier ⌋
Headquarter | Foshan,Guangdong,China |
Branch | Nigeria, Kenya, Senegal, Pakistan, Indonesia, Philippines,etc |
Experience | 16-year+ manufacturer, 17-year+ sales |
Product Series | solar generator system, off grid solar system, solar home lighting system, inverter / ups, solar controller |
Main Market | Africa, Middle East, Asia & South America. (Colombia, Chile, Thailand, Vietnam, South Korea, Syria, UAE, Lebanon, Saudi Arabia, Ghana, Tanzania, South Africa, Spain, Germany, etc.) |
Factory | 10000 Square Meters, 100+ workers |
Department | R&D, Production, Sales, Marketing, Purchasing, QA, After-sale service department |
Certificate | ISO9001:2015, CE, TUV, TLC, IEC, etc. |
Patent | Software Patent, Design Patent, Project Pantent |
⌈ Why So Many Customers Worldwide Choose XINDUN Power ?⌋
Professional
1. More than 50 senior engineers can help solve any inverter technical problems.
2. Have more than 16 years of production and design experience, mainly producing solar inverters and off-grid solar power systems.
3. According to customer requirements, 300W to 200KW off-grid solar power system can be customized. Provide design drawings and configuration design scheme for free.
4. Professional off-grid solar power system installation guide to help users install safely and maintain stably.
Trustworthy
1. We will send you the production process photos every 10 days after you place the order to let you know our production progress.
2. We can accept factory on-site inspection or online inspection before shipment.
Good service
1. One-stop solution, providing installation guidance and after-sales service for the complete off-grid solar power system.
2. Cooperate with many freight forwarders to provide the best transportation cost.
If you are interested in this HP PRO-T inverter with solar charger, feel free to contact XINDUN, discounted price today!!