DP Hybrid Solar Inverter with Inbuilt MPPT/PWM Controller 1KW 1.5KW 2KW
- Pure sine wave AVR output;
- Low frequency toroidal transformer;
- Dedicated DCP chip design, stable and high-speed operation;
- LCD display, easy to monitor the operation condition in real time;
- AC charge current 0-30A adjustable, battery capacity configuration more flexible;
- Three types working modes adjustable: AC first, DC first, energy-saving mode;
- Built-in PWM or MPPT controller optional;
- Added fault codes query function,facilitate user to monitor the operation state in real time;
- Supports diesel or gasoline generator, adapt any tough electricity situation;
- RS232/RS485 communication port/APP optional.
- Description
- Inquiry
Description
⌈Application Area⌋
Office and public facilities, household system, network transmission equipment, manufacturing, control system, solar energy system, oil field, drilling field operation, etc.
Provide stable reliable and safe solutions for families, islandsships and other small photovoltaic power system.
⌈Technical Parameters⌋
Specification | |||
Model DP | 10212/24 | 15212/24/48 | 20212/24/48 |
Rated Power | 1000W | 1500W | 2000W |
Peak Power(20ms) | 3000W | 4500W | 6000W |
Start Motor | 1HP | 1.5HP | 2HP |
Battery Voltage | 12/24VDC | 12/24/48VDC | |
Size(L*W*Hmm) | 555*297*184 | ||
Packing Size(L*W*Hmm) | 620*345*255 | ||
N.W.(kg) | 12 | 13 | 15.5 |
G.W.(kg)(Carton Packing) | 14 | 15 | 17.5 |
Installation Method | Wall-Mounted |
Parameter | ||||||
Input | DC Input Voltage Range | 10.5-15VDC(Single battery voltage) | ||||
AC Input Voltage Range | 85VAC~138VAC / 170VAC~275VAC | |||||
AC Input Frequency Range | 45Hz~65Hz | |||||
Max AC charging current | 0~30A (Depending on the model) | |||||
AC charging method | Three-stage (constant current, constant voltage, floating charge) | |||||
Output | Efficiency(Battery Mode) | ≥85% | ||||
Output Voltage(Battery Mode) | 110VAC±2% / 220VAC±2% / 230VAC±2% / 240VAC±2% | |||||
Output Frequency(Battery Mode) | 50/60Hz±1% | |||||
Output Wave(Battery Mode) | Pure Sine Wave | |||||
Efficiency(AC Mode) | >99% | |||||
Output Voltage(AC Mode) | 110VAC±10% / 220VAC±10% / 230VAC±10% / 240VAC±10% | |||||
Output Frequency(AC Mode) | Tracking Automatically | |||||
Output waveform distortion (Battery Mode) | ≤3%(Linear load) | |||||
No load loss(Battery Mode) | ≤0.8% rated power | |||||
No load loss(AC Mode) | ≤2% rated power( charger does not work in AC mode) | |||||
No load loss(Energy saving Mode) | ≤10W | |||||
Battery Type (selectable) | LEAD | Charge Voltage:14V;Float Voltage:13.8V (12V system; 24V system x2; 48V system x4) | ||||
OP-LE | Charge Voltage:14.2V; Float Voltage:13.8V (12V system; 24V system x2; 48V system x4) | |||||
LITHIUM | Charge Voltage: 12.6V(NMC battery 3S) (12V system; 24V system x2; 48V system x4) | |||||
Customize battery | Charge and discharge parameters of different types of batteriescan be customized according to user requirements | |||||
Protection | Battery undervoltage alarm | 11V; LITHIUM 9.5V(NMC battery 3S) (12V system; 24V system x2; 48V system x4) | ||||
Battery undervoltage protection | 10.5V; LITHIUM 9V(NMC battery 3S) (12V system; 24V system x2; 48V system x4) | |||||
Battery overvoltage alarm | Lead acid battery: 15V (12V system; 24V system x2; 48V system x4) | |||||
Battery overvoltage protection | Lead acid battery: 17V (12V system; 24V system x2; 48V system x4) | |||||
Battery overvoltage recovery voltage | Lead acid battery: 14.5V (12V system; 24V system x2; 48V system x4) | |||||
Overload power protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | |||||
Inverter output short circuit protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | |||||
Temperature protection | >90°C(Shut down output) | |||||
Alarm | A | Normal working condition, buzzer has no alarm sound | ||||
B | Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection | |||||
C | When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal | |||||
Inside Solar controller (Optional) | Charging Mode | PWM or MPPT | ||||
Charging current | 10A~60A | |||||
PV Input Voltage Range | PWM: 15V-44V(12V system); 30V-44V(24V system); 60V-88V(48V system) MPPT: 15V-120V(12V system); 30V-120V(24V system); 60V-120V(48V system) | |||||
Max PV Input Voltage (At the lowest temperature) | PWM: 50V(12V/24V system); 100V(48V system) / MPPT: 150V(12V/24V/48V system) | |||||
PV Array Maximum Power | 12V system: 140W/280W/420W/560W/700W/840W; 24V system: 280W/560W/840W/1120W/1400W/ 1680W; 48V system: 560W/1120W/1680W/2240W/2800W/ 3360W | |||||
Standby loss | ≤3W | |||||
Maximum conversion efficiency | >95% | |||||
Working Mode | Battery First/AC First/Saving Energy Mode | |||||
Transfer Time | ≤4ms | |||||
Display | LCD(External LCD Display(Optional)) | |||||
Thermal method | Cooling fan in intelligent control | |||||
Communication (Optional) | RS232/RS485/APP(WIFI monitoring or GPRS monitoring) | |||||
Environment | Operating temperature | -10℃~40℃ | ||||
Storage temperature | -15℃~60℃ | |||||
Noise | ≤55dB | |||||
Elevation | 2000m(More than derating) | |||||
Humidity | 0%~95% ,No condensation |